Home » Quote » Complete Project Quote

Request a Complete Project Quote

This quote form is intended for simple, standard designs. For more complex designs use our "Upload a Drawing" feature.

Project Details

Vertical Heat Exchanger Information

VHE Reference Illustration
(Click to enlarge)

Please refer to the VHE Reference Illustration to the right to assist in entering information in the fields below.

Total number of Vertical Heat Exchangers
(# boreholes)

Vertical Heat Exchanger depth from grade (feet):
Vertical Heat Exchanger pipe size (u-bend nom pipe size IPS):
U-bend dimension ration (DR):
Grout Information

Please refer to the VHE Reference Illustration above.


Drilled borehole diameter (inches): - Enter a number between 3 and 8
Select grout type:
Grout brand:
Required grout thermal conductivity (BTU/hr-ft-F):

Are GeoClips® U-Bend Pipe Separators Required?

(GeoClips are estimated based on 10-foot spacing)

Circuit Header Information

GeoHeader Reference Illustration
(Click to enlarge)

Please refer to the GeoHeader Reference Illustration to the right.


Total number of circuit headers required:
How many different types of circuit configurations?


Header Configuration Type 1
Grid spacing (spacing between VHEs) (feet):
Circuit header pipe size (Nom pipe size IPS):
Number of VHEs on circuit:
Select the type of circuit header design:
How many of these circuits?

Recommended GeoHeader Model:



Number of Branches:
Wellfield Supplies Is locate tape required?
Is tracer wire required?

Note: Weighted u-bend rods are calculated and included in project estimate.

Circuit Supply and Return Piping Information

Circuit S/R Reference Illustration
(Click to enlarge)

Please refer to the Circuit S/R Reference Illustration to the right.


Enter the piping distance to vault or building's mechanical room (feet):
(Average distance to the beginning of each circuit.)
Vault and Manifold Information  No vault required


GeoVault Reference Illustration
(Click to enlarge)

Please refer to the GeoVault Reference Illustration
to the right.

Main pipe size:
Circuit pipe size determined above in header entries.

Vault circuit location:
Number of supply/return circuits:
Number on left side:   
Number on right side: 

Balancing valves on each circuit:
Fill port size:
Recommended GeoVault Model:
GV GM B R L PT F

Main Supply and Return Piping Information



Vault S/R Reference Illustration
(Click to enlarge)

Please see Vault S/R Reference Illustration to the right.



Piping distance from mechanical room
to vault (feet):

Main Stub-Out Assembly (Pre-fabricated)



Stub-Out Reference Illustration
(Click to enlarge)

 Include pre-fabricated Stub-Out on vault.

Please refer to the Stub-Out Reference Illustration.

Are 2" fill ports required on the mains?
Is a bypass between the mains required?
Include main steel sleeves with LinkSeals®?
Manifold for Mechanical Room Information
Manifold included with Vault.

 No manifold required.
Contact Information
Name:
Title:
Requested by:
Phone number:
Fax:
Email: Confirm email address:
Website:
Project name: Project Location
City: State:
Message:
Would you like one of our engineers to contact you about your project?